จำหน่าย ให้เช่า และติดตั้งระบบภาพและเสียง ระบบรักษาความปลอดภัย เซิร์ฟเวอร์และเครือข่าย
Showing 49–64 of 91 results
– Built-in full-range speaker 5W/8 Ohm with volume control.
– Connecting to the amplifiers or multi-zone speaker selector to monitor the program status.
– Monitors up to 10 speaker zones by using the built-in speaker.
– 6 LED level meters visually indicates the channel signal level.
– Supports 16 zones for BGM and paging.
– Built-in monitor speaker with volume control on front panel.
– Separate input for BGM and paging.
– 70V/100V amplifiered signal input and 16 zone outputs for speakers.
– Each zone has LED indicator.
– 25-pin activation bus.
– Power Handling: maximum 8kW total capacity, maximum 2000W per zone.
– Supports 10 zone speaker selection.
– 2 groups of 5 zones and 70V/100V audio signal outputs.
– Two amplifier inputs A and B.
– LED signal level meter.
– 10-position zone selector switch with pushbutton on the front panel.
– Power handling: maximum 2 kW total capacity, maximum 200W per zone.
– Power handling: maximum 2 kW total capacity, maximum 200W per zone.
– Supports 10 zones for background music,paging, and alarm broadcasting.
– 2 groups of 5 zones and 70V/100V audio signal outputs.
– Two amplifier inputs A and B.
– LED signal level meter.
– 10-position zone selector switch with pushbutton on the front panel.
– 1U compact size with rackmount ears on both front ends.
– The tuner provides the full range of FM frequency from
87.5 to 108MHz, and the AM frequency range is from 522 to 1620KHz.
– Tuning is accomplished by pushbutton with frequency
readout appearing on a backlit LCD display panel.
– Preset stations to memory by storing AM/FM stations
in advance,user can easily recall a broadcast station
by designating the corresponding preset memory channel.
– Push-release connectors are provided for an external AM loop
antenna and FM dipole antennas are included with this unit.
– The alarm panel produces an alarm sound automatically when activated by an external signal or manually by the pushbutton.
– The siren message can be either a built-in siren or a user pre-recorded voice message.
– 60-second digital IC for voice message recording via MIC.or LINE input.
– 16-zone paging selection.
– 16-zone alarm function.
– Volume control.
– Built-in chime,with mute function.
– Each paging zone has LED status indicator.
– One MIC input 6.5mm jack,four remote MIC inputs, one line input, and one EMC input.
– 25-pin activation bus, and low level alarm activation.
Connected by CAT cable with distance up to 1km.
Built in MP3 player with SD and USB ports
Built in chime,with mute function with volume control
– 16X16 Digital Audio Matrix (3U panel).
– With LCD screen in English menu.
– With volume control for each zone.
– This control unit integrates 16 source inputs, 16 amplifier outputs and a priority bus
interface. it can mute background music when ever it has received priority input
signals for zone paging and emergency alarms.
– LCD display and for convenient operation program schedules.
– Priority bus for zone paging and emergency alarms.
– Several paging modes (all zones, group zones, or individual zone) could be achieved
through this paging console.
– The interface can automatically answer an incoming phone call and broadcast the caller’s voice over the PA system.
– Automatic or manual mode optional.
– Built-in monitor speaker and volume control.
– Activation output can be used to trigger other equipment remotely.
– 30 shorted signal inputs for fire alarm,3 groups of 10 channel
shorted signal outputs for fire alarm.
– N±4 adjacent zone range.
– Shorted signal to activate power.
– Address setting with decimal system.
– 2U aluminium panel.
– With 2 channel speaker selector.
– 2 line inputs.
– Individual volume controller for each zone.
– 70V, 100V and 4~16Ω outputs.
– Output short circuit,overload,high temperature protection.
-10 channels of DC24V outputs.
-10 alarm signal inputs provided to activate DC power outputs.
-Each channel has LED indicator.
-25-pin activation input and output bus.
-16 channels of DC24V outputs.
-16 alarm signal inputs provided to activate DC power outputs.
-Each channel has LED indicator.
-25-pin activation input and output bus.
– Connect to 5 main amplifiers and 1 spare amplifier.
– Automatic detection of fault units,and the first fault detected unit will be
automatically switched to the spare unit,other fault units if later detected
will be brought to your attention by the indicators.
– Prompt tone will ring should any main unit fails.
– Indicators have three different indications:Normal,Fault,or Spare.
– Address setting using decimal system.
– 16 power up sequence.
– Total output power rated at 2.5KW.
– Power start using shorted signal from program timer to realize timing power output.